Galeria de Productos
Live Support

Mi Carrito

Usted no tiene artículos en su carrito de compra.

Follow us on Twitter
Twitter.com

Twitter Activities

  • CTSHPLC: Review the recently added Agilent Extended PM Kit for models 1050,1100, and 1200. Search for CTS-11284
    19 days ago
  • CTSHPLC: New Perking Elmer - Series 200 Standard Pump Seals kit added. P/N CTS-11265
    23 days ago
  • CTSHPLC: New 1525 Pump PM Kit added to the CTS catalog. See it by searching for CTS-11282
    27 days ago

Modelo
Int. 4000
1
1000S
100A
1040
1050
1090
10AD
10SC
10WSC
10WTI
1100
110A
110B
112
114M
116
118
119
1200
12020
125
126
127
128
151
1515
152
1000
1515
1525
1525 Micro
1525EF
153
155
156 Dual
160 DAD
163
170 DAD
2
200
200 Series
201
203
204
205
206
206PH
230A
2410
2487
2488
250
25SC
2690
2690D
2695
2695D
2790
2795
2796
2996
3
3000
3100
3200
3500
3B
4
400
4000
410
4100
4200
470
474
480
481
484
486
490
5000
501
510
515
525
590
600
6000
600E
610
616
620
6200
6200A
625
626
655
6700
7000
7010
7040
7067
710
712
7125
7126
715
717
717 Plus
7725
7750
8010
8011
8452A
8453
880
8800
8810
9725
980
996
9A
Acquity
AS-7200
AS100
AS-7250
Biofocus 3000
BIP-1
CapLC
CE100
CE1000
CE2000
CE500
Constametric I
Constametric II
Constametric III
Delta Prep
DSA-1
DU60
DU62
DU64
DU65
DU68
G1265A
G1311
G1312A
G1313
G1315A
G1321
G1327A
G1365A
HPE100
ISOCHROM
L-2450 DAD
L-7100
L-7400
L-7420
L-7450A
L-7455
L2500
L3000
L4000(H)
L4200(H)
L4225
L4250(H)
L4720 Prealigned
L7100
Lambda 2
5
Lambda Max
7
LC 4000
9
LC module1
LC-10AD
10
LC-10ADvp
11
LC-10AS
12
LC-10AT
14
LC-10ATvp
15
LC-20A
16
LC-20AD
17
LC-4000
18
LC-2010
LC-600
19
LC-6A
20
LC-6
LC-7A
25
8A
LC-9A
10AS
35
LC600
40
M440
45
M45
800
M6000
M6000A
900
M6000KA
M6KA
MDL1790
nanoAcquity
P Series
P-1000
P-2000
P-4000
Prep LC3000
Prominence LC-20AD/B
Prep LC4000
Prostar 340
Prostar 345
PU1580
R410
SF757
SF759
SF759A
SF773
SF775
SF783
SF783A
SF785A
SF980
SIL-10A
SIL-10ADvp
SIL-10AI
SIL-10AXL
SIL-6B
SIL-9
SP 8800
SP100
SP200
SP770
SP8480
SP970
SPD-10
SPD-10A
SPD-10AS
SPD-2A
SPD-6A
SPD-6AV
SPD-10Avp
SPD-10AVvp
SPD-20A
Spectrachrom 200
Spectromometer D
Spectromometer I
Spectromometer II
Spectromometer III
TSP P-Series
U6K
UV 6000
UV-Vis
UV100
UV1000
UV150
UV200
UV2000
UV3000
UV500
UV506
VDM-1
WISP

 
Informacion Tecnica

The Wrench

Vol. 6 Issue 1
Winter 2009

Problems with Peak Shape

Poor peak shape can cause a loss of resolution between adjoining peaks, it can lead to poor injection to injection reproducibility, or it may cause an injection to fail method acceptance criteria. Poor peak shape includes issues such as tailing, fronting, split peaks, and shouldered peaks.

The causes of poor peak shape are varied. They include everything from poorly developed methods, to contaminated columns or in other parts of the system, to extra system volume or poor system connections.

The following chart covers some of these common problems and possible remedies.

Problem

Indication

Cause

Solution

Peak Tailing

Tailing Peak

One or a few peaks tailing

Unexpected analyte interaction with solid support or stationary phase

Use base deactivated, or hybrid silica materials. Old style silicas have active sites on the surface that can have unintended interactions with sample analyte

Add a mobile phase modifier to the system such as TEA

All peaks tailing

Poor Connections in system

Ensure that all tubing ends are cleanly and squarely cut.

Make sure that all nuts and ferrules are of the correct shape and tubing depth is correct for all fittings. Different manufacturers have different arrangements, and they are not all interchangeable.

Use PEEK or universal spring loaded connecting tubing.

Void in Column

Replace Column

Dirty guard column

Replace Guard

Dirty column frit

Replace Frit


Peak Fronting

Fronting Peak

Initial Peaks fronting

Too strong a sample solvent

Samples should be dissolved in mobile phase or solvent weaker than mobile phase

All peaks fronting

Column overload

Reduce injection volume

Reduce sample concentrations

Use a column with a larger i.d.

Split Peaks

Split Peaks

Void or channel in column

Replace column

Dirty column frit

Replace frit

Dirty Column

Back flush or replace

Sample solvent not suitable for use with mobile phase

Ensure that sample and mobile phase solvents are compatible – make any necessary adjustments

Peak Shoulders

Peak Shoulders

Shoulder on 1 or 2 peaks

Mobile phase is at a pH near the pKa of the analyte

Adjust pH of mobile phase to be at least 2 pH units away from the pKa of the sample analytes

Adjust mobile phase to separate the 2 peaks

Shoulder on all peaks

Dirty Inlet frit

Replace

Dirty Guard Column

Replace

Dirty Column

Back flush or replace

Top of page

Historical Wrench Articles

Title Issue .pdf
Plunger Seals Vol. 2 Issue 1 Plunger Seal .pdf
HPLC Preventative Maintenance

Vol. 2 Issue 2

Prevt. Maint .pdf
System Backpressure

Vol 2 Issue 3

System Backpressure .pdf
Choosing a Lamp Vendor

Vol 3 Issue 1

Lamp choices .pdf
Instrument Qualification and Aftermarket Parts

Vol.3 Issue 2

IQ and aftermatket .pdf
Material Solvent Compatibility

Vol.4 Issue 1

Solvent Compatibility .pdf
Mobile Phase Buffers

Vol.4 Issue 2

Mobile Phase Buffers .pdf
Sample and Mobile Phase Filtering

Vol.5 Issue 1

Filtering.pdf

Top of Page

© Derechos de Autor 2010 - Chromatography Technology Services
Este sitio esta dedicado al Señor Jesucristo

Inicio | Contáctenos | Mapa del Sitio | Términos de búsqueda | Búsqueda Avanzada
*Los logotipos que aparecen arriba son propiedad de sus respectivos dueños

Feedback X

Send Us Feedback

En CTS, valoramos los comentarios de nuestros visitantes. Gracias de antemano por sus comentarios.


:
:
: